Equipment(s) Inventory

We deliver engineering solutions, which maximize performance across energy-critical industries. 

154 Results

Download PDF

Do you want to download only selected equipment or the entire equipment inventory?

Name Technology Category Quantity Specifications Action

Sulfur Hexafluoride Circuit Breaker

Power Transmission and Distribution Electrical Equipment 1

Brand: SIEMENS, Type: SPS2-145-63-3, Rated Max Volts: 145 kV, Rated Voltage Range Factor: 1.0 (K), Rated Continuous Current: 1200 A, Rated Short Circuit Current: 63000 A, Frequency: 60 Hz, Rated Out of Phase Current: 15800 A, Weight of Breaker with Gas: 8000 lbs, Full Wave Impulse Withstand: 650 kV, Weight of SF6 Gas: 128 lbs, Rated Operating Pressure at 68°F/20°C: 87 psig, Minimum Operating Pressure at 68°F/20°C: 72 psig, SF6 Alarm Pressure at 68°F/20°C: 75 psig, SF6 Cutout Pressure at 68°F/20°C: 72 psig, Serial - S.O.: 30127419-2, Rated Interrupting Time: 3.0 Cycles, Instruction Book: PB-3658-05, Date of Manufacture: 10/13

480 Volt 800 Amp Breakers

Power Transmission and Distribution Electrical Equipment 2

Voltage: 480 V, Current Rating: 800 Amps

90 MVA Transformer

Power Transmission and Distribution Electrical Equipment 1

Power Rating: 90 MVA, Primary Voltage: 138 kV, Secondary Voltage: 13.8 kV

Metering Units (Single Phase Transformer)

Power Transmission and Distribution Electrical Equipment 4

Brand: Trench Limited, Phase: Single Phase, Type: N5H-650, Catalog Number: N5H650138201, BIL kV: 650, Frequency: 60 Hz, N.S.V. kV: 138, Oil Capacity: 70 US GAL, Total Weight: 621 kg, Serial Number: T09142605, Built: 2009, Instruction Book: IME 219.50, Standard: IEEE C57.13

138 kV Surge Arrestors

Power Transmission and Distribution Electrical Equipment 2

Voltage: 138 kV, Type: Surge Arrestor

Siemens 138 kV Circuit Breakers

Power Transmission and Distribution Electrical Equipment 1

Voltage: 138 kV, Interrupting Time: 3 cycles

MHI 138 kV Circuit Breakers

Power Transmission and Distribution Electrical Equipment 1

Voltage: 138 kV, Interrupting Time: 3 cycles

138 kV Disconnects

Power Transmission and Distribution Electrical Equipment 2

Voltage: 138 kV, Operation Type: Manual/Remote, Insulation Type: Air

Virginia 10MVA Transformer

Power Transmission and Distribution Electrical Equipment 1

MVA rating: 10 MVA, Voltage: 26 kV, 1000 V, SL No: 45010MA002U - HA371A, Number of Phases: 3, Frequency: 60 Hz, Class: ONAN, HV: 26000 Y, BIL (High Voltage): 200 kV, BIL (Low Voltage): 110 kV, kVA: 10000, Temperature Rise: 149°F (65°C), Winding Material: Copper, Impedance: 14.00% AT 26000-1000V & 10000kVA, Month/Year of Manufacture: 2/2014

Efacec 33MVA Transformer

Power Transmission and Distribution Electrical Equipment 1

brand: Efacec, mva_rating: 33, voltage: 26 kV, 6.9 kV

Efacec 76MVA Transformer

Power Transmission and Distribution Electrical Equipment 2

MVA rating: 76 MVA, Voltage: 26 kV, 6.9 kV, Serial No: E1100032A, Standards: IEEE.C57.12.00.2010, Month / Year of Manufacturing: 09/2013, Instruction Book Reference: E1100032A, Winding Material: Copper, Oil Preservation System: Conservator Tank, Insulating Oil: Mineral Oil, Sound Pressure Level (ONAN): 77.0 dB(A), Frequency: 60 Hz, Temperature Rise: 65 °C, Number of Phases: 3, Vector Group / Polarity: Dyn11yn11

Toshiba 460MVA Transformer

Power Transmission and Distribution Electrical Equipment 4

MVA ratings: 460 MVA, 460 MVA, Frequency: 60 Hz, Number of Phase: 1, Voltage rating: 231.6 GrdY/133.7 kV, 26 kV, Standard: IEEE Std C57.12.00-2006, Cooling Type: ODAF, Temperature Rises: 65 °C, 65 °C, 80 °C, Serial No: 15900004, Manufactured In: 2015, Instruction Book No: E-3586313, Conductor Material: Copper, Polarity: Subtractive

ABB RESIBLOC 3 Phase 4.200kv Transformer

Power Transmission and Distribution Electrical Equipment 1

Phase: 3, Rated Power: 4200//1300/1300/1600, Rated Voltage: 1100//410/410/729, Rated Current: 220.4//1831/1831/1267, Frequency: 60Hz, Cooling Type: AFWF, Max System Voltage: 12//1.1/1.1/1.1, Year: 2019/2020

ABB RESIBLOC 3 Phase 11.000kv Transformer

Power Transmission and Distribution Electrical Equipment 1

Rated Power: 1100//5500/5500, Rated Voltage: 1100//1682/1678, Rated Current: 577.4//1888/1892, Frequency: 60Hz, Type of Cooling: AFWF, Max System Voltage: 12//3.6/3.6, Year: 2019/2020